56050000 hex

Unassigned Logical CNC Motor Number Specified

Omron · NJ/NY-series NC Integrated Controller

Hva betyr 56050000 hex ?

This minor fault indicates that a CNC instruction was executed with a `LogicalMotorNo` input variable referencing a CNC motor that has not been assigned. The fault is detected during instruction execution within the CNC coordinate system of the CNC Function Module. This will prevent the instruction from executing and cause the relevant CNC coordinate system to stop immediately if it is moving.

Vanlige årsaker

  • The `LogicalMotorNo` input variable of a CNC instruction specifies a motor number that is not configured or assigned in the system.
  • The specified logical CNC motor number falls outside the range of motors assigned for `Positioning Axis Assignment` or `Spindle Axis Assignment` within the CNC coordinate system parameter settings.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Review the CNC program to identify the instruction specifying the `LogicalMotorNo` input variable.

  2. 2

    Verify the current CNC coordinate system parameter settings for `Positioning Axis Assignment` and `Spindle Axis Assignment`.

  3. 3

    Correct the `LogicalMotorNo` parameter in the instruction to refer to an actual assigned logical CNC motor number.

  4. 4

    Alternatively, assign the intended CNC motor to the specified `LogicalMotorNo` within the CNC coordinate system parameter settings.