56000000 hex
Illegal CNC Coordinate System Specification
Omron · NJ/NY-series NC Integrated Controller
Hva betyr 56000000 hex ?
A minor fault detected at instruction execution, indicating that the CNC coordinate system specified for the Coord in-out variable of a CNC instruction does not exist. This fault, originating from the CNC Function Module common part, prevents the relevant instruction from executing, though the user program continues.
Vanlige årsaker
- The Coord in-out variable within a CNC instruction references a CNC coordinate system that is not defined or configured.
- A programming error has supplied an invalid or non-existent coordinate system name as an input parameter to a CNC instruction.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Review the CNC instruction to identify the value or variable assigned to the Coord in-out parameter.
- 2
Verify the existence and correct definition of the CNC coordinate system referenced by the Coord variable within the controller configuration.
- 3
Modify the instruction's input parameter to specify an existing and valid CNC coordinate system.