ACTM Error
Mitsubishi Electric · PUZ-HA30/36NHA4 Outdoor Unit
Hva betyr 20 ?
An error related to the Automatic Current Tracking Module (ACTM) has occurred. This module is essential for accurate current sensing and control, and an error can impact compressor operation and protection, often associated with the power board.
Vanlige årsaker
- Error detected by the ACTM (Active Current Transformer Module).
- Faulty current transformer.
- Issue with the current sensing circuitry.
- Overload condition causing abnormal current readings.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check the CNAF wiring connections for proper seating and continuity.
- 2
Inspect the ACTM module on the power board for any visible damage.
- 3
Inspect the power circuit board (P.B) for any visible defects or component failure.
Verifisert teknisk data. Sist oppdatert: March 2026