Oversetter...
26040

Heat sink temperature too high, KPP/KSP (axis)

Kuka · KR C4 extended

Hva betyr 26040 ?

The heat sink temperature on the KPP or KSP module for a specific axis is too high, indicating an overtemperature condition. This can lead to overheating and potential damage to the drive components if not addressed.

Vanlige årsaker

  • Cabinet fan is not functioning or obstructed.
  • Ambient temperature in the cabinet is excessively high.
  • Program load is too high for the drive, leading to excessive heat generation.
  • Cooling circuit is obstructed by dirt.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Inspect cabinet fan for operation and obstructions.

  2. 2

    Verify ambient temperature around the controller.

  3. 3

    Review robot program to identify and reduce excessive load on the axis.

  4. 4

    Clean cooling circuit and heat sink fins.

  5. 5

    Check installation site for adequate ventilation slits and clearance.

  6. 6

    Reinitialize the drive bus: Power Off / Power On.

Se alle koder i denne manualen (35)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder