Oversetter...
26032
IxT overload error, KPP/KSP (axis)
Kuka · KR C4 extended
Hva betyr 26032 ?
The axis is overloaded, indicated by the IxT (Current x Time) monitoring function. This fault suggests that the mean continuous current is too high, potentially leading to overheating and damage to the motor or drive.
Vanlige årsaker
- Excessive load in the program during start-up or operation.
- Modifications made to the system (e.g., increased payload, changed mechanics).
- Temperature influences (e.g., high ambient temperature).
- CBS pressure issue.
- Gear unit fault.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Review robot program to identify and reduce excessive load.
- 2
Reinitialize the drive bus: Power Off / Power On.
- 3
Check machine for mechanical issues or resistance.
- 4
Check trace recording of axis current.
- 5
Adapt program velocity to reduce continuous load.
- 6
Check CBS pressure.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Kuka KR C4 extended