LL

Machine Tilted

Kone · Elevator Control

Hva betyr LL ?

The machine has detected a tilt condition beyond acceptable limits, indicating a potential stability risk. This critical condition disables both lifting and driving.

Vanlige årsaker

  • Machine operating on an uneven surface or exceeding the maximum allowable slope.
  • Tilt sensor malfunction or incorrect calibration.
  • Unstable ground conditions.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify the physical level and stability of the elevator car/machine using appropriate leveling tools.

  2. 2

    Inspect the tilt sensor unit (inclinometer) for physical damage, debris, or improper mounting/alignment.

  3. 3

    Check all associated wiring and connectors between the tilt sensor and the Kone Elevator Control unit for loose connections, damage, or corrosion.

  4. 4

    Verify the reported status of the tilt sensor in the Kone Elevator Control's diagnostic interface to confirm the sensor's current output signal.

Se alle koder i denne manualen (60)
Verifisert teknisk data. Sist oppdatert: March 2026