68

Battery Low Voltage

Kone · Elevator Control

Hva betyr 68 ?

The battery voltage is critically low, impacting machine operation. This condition is severe enough to disable all motion functions.

Vanlige årsaker

  • Battery discharged below operational threshold.
  • Aging battery with reduced capacity or damaged cells.
  • Faulty voltage measurement circuit giving an inaccurate low reading.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Measure the actual voltage of the Kone Kone Elevator Control's backup battery at its terminals using a calibrated multimeter.

  2. 2

    Inspect all battery cable connections and associated wiring for corrosion, looseness, or physical damage.

  3. 3

    Check the input power supply to the battery charging module and verify its output voltage to ensure proper charging function.

  4. 4

    Verify any relevant battery monitoring parameters or thresholds within the Kone Kone Elevator Control system's diagnostics.