59 Parallel Coil Fault

Kone · Elevator Control

Hva betyr 59 ?

A fault has been detected in the parallel coil, indicating an electrical issue with this specific solenoid. This disables both lifting and driving functions.

Vanlige årsaker

  • Parallel coil open circuit, short circuit, or high resistance.
  • Damaged wiring or loose connections to the parallel coil.
  • Control circuit failure attempting to activate the coil.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify the identification and physical location of the 'parallel coil' solenoid within the Kone Kone Elevator Control system schematics.

  2. 2

    Inspect all associated wiring, connectors, and terminals of the parallel coil solenoid for damage, loose connections, or corrosion.

  3. 3

    De-energize the system. Measure the resistance of the parallel coil solenoid across its terminals and compare the reading to the nominal value specified in the electrical documentation.

  4. 4

    Energize the system. Measure the supply voltage at the parallel coil solenoid terminals when commanded to activate, ensuring it matches the specified operating voltage.