57
57 Steer Left Coil Fault
Kone · Elevator Control
Hva betyr 57 ?
A fault has been detected in the steer left coil, indicating an electrical issue with the solenoid responsible for steering left. This disables both lifting and driving functions.
Vanlige årsaker
- Steer left coil open circuit, short circuit, or high resistance.
- Damaged wiring or loose connections to the steer left coil.
- Control circuit failure attempting to activate the coil.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify the supply voltage at the steer left coil solenoid terminals against the nominal specification.
- 2
Inspect all wiring and connections leading to and from the steer left coil solenoid for looseness, damage, or corrosion.
- 3
Measure the electrical resistance of the steer left coil solenoid to identify an open circuit or short circuit condition.
- 4
Verify the discrete output signal from the elevator control unit intended to energize the steer left coil solenoid.
Verifisert teknisk data. Sist oppdatert: March 2026