Chassis Up or Down Switch ON
Kone · Elevator Control
Hva betyr 12 ?
The chassis up or down switch is detected in an ON position, potentially causing unintended chassis movement. This condition disables chassis control.
Vanlige årsaker
- Chassis Up or Down switch stuck in an active state.
- Wiring fault causing the switch input to be continuously active.
- Mechanical issue preventing the switch from returning to neutral.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Inspect the mechanical operation and physical condition of the "Chassis Up" and "Chassis Down" switches for any sticking, damage, or foreign material preventing full return to the OFF position.
- 2
Measure the electrical continuity or voltage output of each "Chassis Up" and "Chassis Down" switch in both activated and deactivated states to confirm proper electrical switching.
- 3
Check the wiring integrity and connections from the "Chassis Up" and "Chassis Down" switches to the Kone Kone Elevator Control input module for any shorts, loose terminals, or insulation damage.
- 4
Verify the real-time input status of the "Chassis Up" and "Chassis Down" signals within the Kone Kone Elevator Control's diagnostic interface or PLC monitoring tools, comparing it to the physical switch state.