Synchr. Diff. A2
Indramat · ServoDyn D Servo Drive
Hva betyr 38 ?
The "Synchronization Difference A2" error occurs when the position difference between Axis 1 and Axis 2 motors exceeds the value configured in Parameter 40 (Synchr. Diff. A2). This indicates a loss of coordinated motion between the synchronized axes.
Vanlige årsaker
- The actual position difference between Axis 1 and Axis 2 motors is greater than the allowed tolerance set in Parameter 40.
- Parameter 40 is set too low for the application, making the synchronization tolerance too tight.
- Mechanical binding, excessive load, or friction on either Axis 1 or Axis 2 prevents proper synchronized movement.
- Incorrect tuning of the position gains (Parameters 05 and 45) for the synchronized axes.
- Faulty encoder feedback or drive performance on either Axis 1 or Axis 2.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify that the parameter entries for Axis 1 and Axis 2, particularly feed constants and encoder data, are identical.
- 2
Inspect both Axis 1 and Axis 2 for any signs of skewing or mechanical binding that could hinder synchronized movement.
- 3
Increase the value of Parameter 40 (Synchr. Diff. A2) if the application tolerates a larger synchronization difference.
- 4
Review and optimize the position control loop tuning for both Axis 1 (Parameter 05) and Axis 2 (Parameter 45).
- 5
Check the encoder feedback signals from both axes for accuracy and consistency.