Oversetter...
33

No Marker Pulse2

Indramat · ServoDyn D Servo Drive

Hva betyr 33 ?

This error occurs if the marker pulse from the Axis 2 encoder is not detected within one full rotation during the Axis 2 homing cycle, or if a continuous marker pulse signal is present. This points to a problem with the marker pulse feedback for Axis 2.

Vanlige årsaker

  • Disconnected or faulty wiring for the marker pulse at CLM01.3-M connector X2, pins 3 and 4.
  • Defective Axis 2 encoder, failing to generate a marker pulse or generating a continuous pulse.
  • Incorrectly set homing parameters (e.g., Parameter 48 or 49) preventing proper marker pulse search for Axis 2.
  • Noise or interference on the encoder feedback lines disrupting Axis 2 marker pulse detection.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Switch the marker pulse wires at CLM01.3-M connector X2, pins 3 and 4 (if incorrect polarity is suspected).

  2. 2

    Verify that the Axis 2 encoder is correctly installed and free from physical damage.

  3. 3

    Inspect the Axis 2 encoder cable for any signs of damage, shorts, or poor shielding.

  4. 4

    Review Parameter 48 (Homing Setup A2) and Parameter 49 (Homing Offset A2) for Axis 2 to ensure proper homing configuration.

  5. 5

    If possible, use an oscilloscope to check for the presence and quality of the marker pulse signal directly at the encoder and at the CLM01.3-M input.

Se alle koder i denne manualen (51)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Indramat ServoDyn D Servo Drive