FeedAngle Loss 2
Indramat · ServoDyn D Servo Drive
Hva betyr 31 ?
This error occurs if the feed angle auxiliary input, configured in Parameter 54 (Monitoring A2), drops to a low signal state while Axis 2 is in motion. This indicates a loss of feedback critical for synchronized operation or process control.
Vanlige årsaker
- Loss of the feed angle auxiliary input signal to the CLM01.3-M during Axis 2 movement.
- Faulty wiring or loose connection of the feed angle auxiliary input to the CLM01.3-M.
- Malfunctioning feed angle sensor or its signal conditioning circuitry.
- Incorrect configuration of Parameter 54 (Monitoring A2) for the expected input signal type.
- The press speed is too high or the part length too long for continuous operation with feed angle monitoring.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify that the feed angle auxiliary input wiring to the CLM01.3-M is properly connected and secure.
- 2
If the feed angle is from a continuously operating press, consider slowing the press speed or reducing the part length to maintain signal integrity.
- 3
Inspect the feed angle sensor for proper operation, cleanliness, and mechanical integrity.
- 4
Review Parameter 54 (Monitoring A2) to ensure it is configured for the correct auxiliary input and expected signal characteristics.
- 5
Check the cabling from the feed angle sensor to the CLM01.3-M for continuity and shielding effectiveness against noise.