EOS Cmd Missing
Indramat · ServoDyn D Servo Drive
Hva betyr 18 ?
The "EOS Command Missing" error occurs when the CLM01.3-M user program fails to execute an EOS (End of Synchronization) command where required, specifically at the end of a flying cutoff cycle. This error also triggers if LMD, LML, or LMR commands are encountered before EOS.
Vanlige årsaker
- The EOS command is omitted from the end of a flying cutoff cycle in the user program.
- LMD (Part Length Via The IDS Board), LML (Part Length), or LMR (Part Length With Registration) commands are executed before the EOS command.
- A program logic error causes the EOS command to be bypassed or skipped.
- Corrupted user program data leading to misinterpretation of commands.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify that the EOS command is correctly programmed at the end of every flying cutoff cycle as described in Chapter 5 (Programming).
- 2
Ensure that LMD, LML, or LMR commands are not executed before the EOS command within the program flow.
- 3
Review the user program logic to confirm that the EOS command is always reached and executed at the appropriate point.
- 4
If necessary, explicitly insert the EOS command into the program sequence where it is required.
- 5
Test the flying cutoff cycle thoroughly in both Manual and Automatic modes to ensure correct program sequencing and command execution.