14

Invalid Block #

Indramat · ServoDyn D Servo Drive

Hva betyr 14 ?

This error indicates that a jump or branch command within the CLM01.3-M user program is attempting to direct program execution to a block number greater than 999, which is outside the valid range for program blocks.

Vanlige årsaker

  • A jump or branch command in the user program specifies a target block number exceeding 999.
  • Typographical error during program entry, leading to an incorrect, out-of-range block number.
  • Logical error in the user program causing an unintended jump to an invalid block.
  • Parameter 84 (Start Task 2 & 3) is enabled with an invalid program block location.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Review the CLM01.3-M user program to identify any jump or branch commands (e.g., JMP, JSR) that specify a target block number greater than 999.

  2. 2

    Correct the target block numbers in the user program to be within the valid range of 000-999.

  3. 3

    If Task 3 is being used, ensure that the Task 3 program is located within a valid program block range as specified in Parameter 84.

  4. 4

    Re-test the program after corrections to ensure all jumps and branches execute to valid program blocks.

  5. 5

    Perform a thorough debug of the program logic, especially for conditional jumps, to prevent accidental jumps to invalid addresses.

Se alle koder i denne manualen (51)