Emergency Stop
Indramat · ServoDyn D Servo Drive
Hva betyr 03 ?
This error signifies that the Emergency Stop circuit has been activated, interrupting the +24 Vdc signal to the CLM01.3-M's Emergency Stop input (connector X3, pin 3). This immediately halts machine operation to ensure safety.
Vanlige årsaker
- An Emergency Stop pushbutton has been pressed on the machine.
- Break or fault in the wiring of the machine's Emergency Stop circuit.
- Loss of +24 Vdc supply to the Emergency Stop input (connector X3, pin 3).
- Malfunctioning Emergency Stop switch or associated relay contacts.
- Incorrect wiring of the Immediate Stop input, causing a false trigger.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify that no Emergency Stop pushbuttons are pressed or latched in the 'active' position.
- 2
Check the machine builder's wiring diagrams for the Emergency Stop circuit to locate the fault source.
- 3
Measure for +24 Vdc at CLM01.3-M connector X3, pin 3 to confirm the input signal status.
- 4
Inspect the Emergency Stop wiring from the pushbutton to the CLM01.3-M for continuity, shorts, or loose connections, especially at connector X3.
- 5
Ensure the +24 Vdc supply to the Emergency Stop input (X3, pin 3) is stable and within voltage tolerance, also check +24VDC at CLM01.3-M connector X5, pins 1 and 2 and X3, pins 36 and 37.