27
Battery Not Supported
Fronius · Perfect Charging
Hva betyr 27 ?
The connected battery's characteristics (e.g., chemistry, nominal voltage, communication protocol) are not recognized or supported by the battery charger. This prevents the charger from safely or correctly initiating a charge cycle.
Vanlige årsaker
- Connecting a battery type (different chemistry, nominal voltage, or communication interface) that the charger is not designed to support.
- Incorrect charger configuration for the connected battery type, or missing necessary charging profiles.
- Missing or corrupted battery identification data (e.g., TagID) that the charger relies upon to recognize the battery.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify the type and specifications of the connected battery against the charger's compatibility list or documentation.
- 2
Check the charger's settings and parameters to ensure they are configured for the correct battery type, nominal voltage, and chemistry.
- 3
Ensure that the battery's TagID or communication module (if present) is functioning and transmitting valid identification data to the charger.