101
Gateway CAN Connect Timeout
Fronius · Perfect Charging
Hva betyr 101 ?
The 'CAN Connect' setting is active on the charger, but no CAN connection could be established to the gateway device for a continuous period of at least 2 minutes. This means the charger cannot exchange data with the gateway, which is critical for remote monitoring or control.
Vanlige årsaker
- A disconnected or physically damaged CAN bus cable between the charger and the gateway device.
- The gateway device is not powered on, has crashed, or is otherwise faulty and unable to respond to CAN communication.
- Incorrect CAN bus settings (e.g., baud rate, termination) or an addressing conflict between the charger and the gateway.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify the physical CAN bus cable connection between the charger and the gateway device for integrity and secure mating.
- 2
Ensure the gateway device is powered on and operating correctly by checking its indicator LEDs or internal diagnostics.
- 3
Check CAN bus termination resistor values and configuration settings on both the charger and the gateway to ensure they are correctly set for the network topology.