203

TagID CAN Communication Failed

Fronius · Perfect Charging

Hva betyr 203 ?

CAN communication with the battery's TagID module could not be established. This prevents the charger from reading critical battery identification, configuration, and operational data, making proper charging impossible.

Vanlige årsaker

  • A disconnected or physically damaged CAN bus cable connecting the charger to the TagID module.
  • The TagID module itself is faulty, not powered, or its CAN interface has failed.
  • Incorrect CAN bus settings such as baud rate, or improper termination resistors for the TagID connection.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify the physical CAN bus cable connection to the TagID module for integrity and secure mating.

  2. 2

    Check the TagID module for power presence and its operational status (e.g., indicator LEDs, if any).

  3. 3

    Inspect CAN bus termination resistors and baud rate settings to ensure they are correctly configured for the network.