Oversetter...
ER04

PMC TYPE UNMATCH

Fanuc · Series 0i-D/0i Mate-D Maintenance

Hva betyr ER04 ?

This Fanuc Series 0i-D/0i Mate-D PMC alarm indicates that the PMC type specified in the sequence program does not match the actual PMC hardware installed in the machine. This mismatch prevents the program from being executed correctly.

Vanlige årsaker

  • The sequence program was created or configured for a different PMC type.
  • The actual PMC hardware installed does not match the type specified in the program.
  • Incorrect PMC type selection during the programming process.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Use the PMC programmer to verify the PMC type specified within the sequence program.

  2. 2

    Confirm the actual physical PMC module installed in the machine and its specific model designation.

  3. 3

    Modify the sequence program using the PMC programmer to ensure it specifies the adequate PMC type that matches the installed hardware.

  4. 4

    Ensure that the PMC module has the correct firmware version compatible with the specified PMC type in the program.

  5. 5

    If the sequence program is correct for its intended PMC, ensure the correct PMC hardware module is installed for the machine configuration.

Se alle koder i denne manualen (60)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Fanuc Series 0i-D/0i Mate-D Maintenance