Oversetter...
361

ABNORMAL PHASE DATA(INT)

Fanuc · Series 0i-D/0i Mate-D Maintenance

Hva betyr 361 ?

This alarm on Fanuc Series 0i-D/0i Mate-D with αi/βi Pulsecoders indicates a communication error or ID data error within the built-in Pulsecoder, suggesting a potential failure of the Pulsecoder itself or interference from external noise.

Vanlige årsaker

  • Communication error in the Pulsecoder due to faulty internal components.
  • ID data error within the Pulsecoder's signal processing.
  • Pulse coder failure due to aging or internal defect.
  • Electrical noise interfering with Pulsecoder communication.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check for sources of electromagnetic interference (EMI) or noise near the Pulsecoder cable and servo amplifier; mitigate if found.

  2. 2

    Inspect the Pulsecoder cable and its connectors for any signs of damage, proper seating, and secure connections.

  3. 3

    Verify that the Pulsecoder cable shield is properly grounded at the servo amplifier side.

  4. 4

    If noise, cabling, and connections are confirmed to be in good condition, replace the Pulsecoder unit.

Se alle koder i denne manualen (60)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Fanuc Series 0i-D/0i Mate-D Maintenance