ER01

PROGRAM DATA ERROR

Fanuc · Series 0i-D/0i Mate-D Maintenance

Hva betyr ER01 ?

This Fanuc Series 0i-D/0i Mate-D PMC alarm indicates that the sequence program (ladder program) is invalid. This can be caused by incorrect program entry or a hardware fault within the PMC.

Vanlige årsaker

  • Incorrect sequence program data entry or corruption during loading.
  • Logical or syntax errors within the sequence program.
  • Hardware fault within the PMC module or its memory.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Re-enter or reload the sequence program (ladder program) using the PMC programmer.

  2. 2

    Verify the integrity of the sequence program data against a known good backup file.

  3. 3

    Check for any syntax errors, unsupported functions, or logical inconsistencies in the re-entered program.

  4. 4

    If the error recurs even after correctly re-entering the program, consider a potential hardware issue with the PMC module.

  5. 5

    Inspect the PMC module and its connections for any physical damage or loose components.