Oversetter...
A

Cooling Fan Stop (ECM)

Fanuc · Macro B CNC Programming

Hva betyr A ?

The cooling fan for the heat sink of the Energy Charge Module's (ECM) Control Module has stopped. This will lead to overheating of the Control Module, potentially shortening component life or triggering other temperature-related alarms (e.g., Over-heat of Control Module, LED 9).

Vanlige årsaker

  • Cooling fan for the ECM or motor has stopped operating.
  • Fan motor failure or obstruction.
  • Faulty fan control circuit (P24-1).
  • Overheating due to inadequate heat dissipation.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Immediately stop the machine using the emergency stop button and open the external Main Circuit Contactor (MCC) of the Power supply.

  2. 2

    Inspect the cooling fan of the ECM Control Module (A06B-6158-H010) for any physical obstructions (dust, debris) preventing its rotation.

  3. 3

    Check the fan motor's power connection and verify the voltage supply to the fan.

  4. 4

    Test the fan motor for functionality. If it is faulty or damaged, replace the cooling fan unit.

  5. 5

    Ensure ambient temperature and ventilation within the cabinet are adequate to prevent over-reliance on the fan and ensure efficient heat dissipation (Section G.2.3, page 460).

Se alle koder i denne manualen (26)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder