0x8002
UPS Communication Error
Beckhoff · CX2100-0914 Embedded PC
Hva betyr 0x8002 ?
The function block output `nErrId` shows 0x8002, indicating that communication with the Uninterruptible Power Supply (UPS) has been interrupted. This prevents the system from reading UPS status or sending control commands.
Vanlige årsaker
- Communication link between the system and the UPS is broken.
- UPS is offline or not powered.
- Incorrect serial or network connection to the UPS.
- Faulty UPS communication interface.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check the physical communication cable (e.g., USB, serial) between the Embedded PC and the UPS for loose connections, damage, or dislodgement.
- 2
Verify the UPS power supply and operational status directly on the UPS unit itself. Ensure it is powered on and functioning.
- 3
Confirm that the Beckhoff UPS software components and relevant drivers are correctly installed and running on the Embedded PC's operating system.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Beckhoff CX2100-0914 Embedded PC