61

Speed Error

Vacon · NX All-in-One Application

¿Qué significa 61 ?

The measured motor speed deviates significantly from the commanded speed reference. For Permanent Magnet Synchronous (PMS) motors, this can also indicate that the motor has exceeded its pull-out torque, leading to loss of synchronization.

Causas comunes

  • Motor speed deviates significantly from the setpoint (e.g., P1-01).
  • Inadequate torque to maintain speed under load.
  • Encoder feedback issues (e.g., lost pulses, incorrect resolution).
  • Tuning parameters (e.g., P2-01 to P2-06) not optimized.
  • Mechanical system exhibiting resonance or instability.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Inspect the encoder connection and wiring to ensure proper speed feedback to the drive.

  2. 2

    Verify motor loading and ensure the motor is not operating beyond its pull-out torque capacity, especially for PMS motors.