Traduciendo...
FF0208h

Lag Error Exceeded

SEW Eurodrive · MOVI-PLC SyncCrane Application

¿Qué significa FF0208h ?

This fault occurs when the defined lag error window is exceeded in automatic mode. The lag error represents the distance from the external encoder position to the virtual master encoder position. Exceeding this set tolerance causes the axis system to stop to maintain synchronized operation.

Causas comunes

  • The actual position deviates from the commanded position beyond a defined tolerance.
  • Motor encoder feedback is not keeping up with motion demands.
  • Inadequate servo loop tuning leading to excessive tracking error.
  • Mechanical load or inertia exceeding controller capabilities.
  • High acceleration or velocity commands causing position lag.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Review the configured 'Lag error window' startup parameter to ensure it is appropriate for the application's synchronization requirements.

Ver todos los códigos en este manual (9)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: SEW Eurodrive MOVI-PLC SyncCrane Application