Traduciendo...
FF0202h

Invalid Axis Selection

SEW Eurodrive · MOVI-PLC SyncCrane Application

¿Qué significa FF0202h ?

This fault occurs when an invalid axis number is selected for control. For group control, Process Output Data word PO3 must be set to 99. For single axis control, PO3 must be set to a value between 1 and 8, corresponding to the specific axis.

Causas comunes

  • An invalid axis identifier was used in a command or configuration.
  • Attempting to control an axis that has not been properly initialized or configured.
  • Selection of a non-existent or disabled axis in a multi-axis system.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the value of process output data word PO3 (Axis number selection) — ensure it is 99 for group control.

  2. 2

    Verify the value of process output data word PO3 (Axis number selection) — ensure it is a value between 1 and 8 for single-axis control.

Ver todos los códigos en este manual (9)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: SEW Eurodrive MOVI-PLC SyncCrane Application