FF0203h
Software Limit Switch CW Exceeded
SEW Eurodrive · MOVI-PLC SyncCrane Application
¿Qué significa FF0203h ?
This fault indicates that the specified position or the actual position of an axis has moved beyond the defined clockwise (CW) software limit switch. This condition prevents further movement in the CW direction and halts the axis system to prevent overtravel.
Causas comunes
- Axis position exceeded the defined clockwise software limit switch.
- Encoder feedback indicates movement beyond the maximum allowed CW position.
- Incorrectly set CW software limit parameter.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Review and adjust the clockwise software limit parameter (e.g., P5-42) to a higher value.
- 2
Manually move the axis to a safe position within the limits.
- 3
Check the actual encoder position reading (e.g., P5-03) to confirm it is within the new limits.
- 4
Verify the jog speed setting to prevent overshoot during manual movements.
Datos técnicos verificados. Última actualización: March 2026