Communication error
Schindler · Easy Altivar ATV310 Drive
¿Qué significa COM.E ?
This communication error indicates a 50 ms timeout, appearing after 220 retry attempts. It signifies a problem with the communication link between the drive and the remote display terminal, preventing proper data exchange.
Causas comunes
- A 50 ms communication timeout error between the drive and the display terminal.
- Loose or faulty wiring connections for the communication cable.
- Electromagnetic interference affecting the communication line.
- Incompatible communication settings between the display terminal and the drive.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check the physical communication wiring between the display terminal and the drive for secure connections and proper termination.
- 2
Inspect the communication cable for any signs of damage, wear, or incorrect routing that could lead to interference.
- 3
Verify that the communication settings (e.g., protocol, address, baud rate) on both the display terminal and the drive are correctly configured and match.
- 4
Ensure that both the drive and the display terminal are properly powered and that power supplies are stable.