A-17

Key alarm

Schindler · Easy Altivar ATV310 Drive

¿Qué significa A-17 ?

The Key alarm indicates an issue with the display terminal's keypad. This fault is triggered if a key remains pressed for longer than 10 seconds, if the membrane switch is disconnected, or if the display terminal powers on while a key is already depressed.

Causas comunes

  • A key on the display terminal is stuck in the pressed position for an extended period (over 10 seconds).
  • The membrane switch of the display terminal is disconnected or has failed internally.
  • The display terminal was woken up or powered on with one or more keys already pressed.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Inspect the display terminal keypad for any physically stuck keys and gently clean around them to ensure free movement.

  2. 2

    Check the connection of the membrane switch to the display terminal's PCB, ensuring it is properly seated.

  3. 3

    Ensure no keys are pressed when the display terminal is powered on or woken up.

  4. 4

    If the fault persists after checking the keypad, consider replacing the display terminal as the membrane switch or internal components may be faulty.

Ver todos los códigos en este manual (37)
Datos técnicos verificados. Última actualización: March 2026