RSL Parity Error
Otis · GAA21750AK3 Service Tool
¿Qué significa 0400 RSL parity ?
This event log entry indicates a parity error occurred on the Remote Serial Link (RSL) at address '0400'. This error signifies data corruption during transmission over the RSL, which can lead to unreliable communication with remote stations and potential system blocking for the LCB_II.
Causas comunes
- Electrical noise or interference on the RSL communication lines.
- Damaged or degraded RSL cabling.
- Incorrect RSL termination resistor settings.
- Faulty RSL transceiver module at address '0400' or on the main LCB_II board.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Inspect the RSL communication cable for physical damage, proper shielding, and secure connections.
- 2
Verify the RSL termination resistors are correctly installed and set at both ends of the communication bus.
- 3
Check for sources of electromagnetic interference (EMI) near the RSL wiring.
- 4
Perform a bus resistance measurement if applicable, expecting specific resistance values.
- 5
Replace the RSL module at address '0400' if the error persists after verifying wiring and environment.