Low read-back volts from DC bus circuit.
Otis · DSD 412 Elevator System
¿Qué significa 938 ?
This fault indicates that a low voltage read-back is detected from the DC bus circuit. This can occur during Self-Tune (Function #997) or Self-Diagnostic (Function #998). For drives larger than 300 amps DC, this involves discrete wires.
Causas comunes
- Missing wire connected to the bus voltage feedback circuit.
- Component problem where the feedback voltage divider ratio does not match the one identified in the Cube ID PCB.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check for any missing wires connected to the bus voltage feedback circuit.
Datos técnicos verificados. Última actualización: March 2026