410
SPEED ERROR TRIP FAULT
Otis · DSD 412 Elevator System
¿Qué significa 410 ?
This fault causes an automatic drive shutdown when speed errors exceed the threshold defined by Function #100 for a duration longer than specified by Function #99 (Speed Error Trip Time).
Causas comunes
- Speed errors exceeding the magnitude set in Function #100 for a period longer than Function #99.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the setting of Function #99 (Speed Error Trip Time) and adjust if the system response time is longer than configured.
- 2
Verify the setting of Function #100 (Speed Error Trip Threshold) and adjust if the allowable speed deviation is different.
- 3
Investigate the root cause of speed errors, such as mechanical load changes or feedback issues.