405
SAFETY CIRCUIT FAULT
Otis · DSD 412 Elevator System
¿Qué significa 405 ?
The DSD 412 drive detects that the Safety Circuit, connected between terminals TB3-1 and TB3-6 on the power supply, unexpectedly opened while the drive was in run mode. The safety chain must be closed for at least 100ms before enabling the drive. This fault is disabled if the speed is below the low speed threshold defined by parameter #64.
Causas comunes
- Intermittent connections within the Safety Chain.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check for intermittent connections in the Safety Chain wiring between terminals TB3-1 and TB3-6 on the power supply.
Datos técnicos verificados. Última actualización: March 2026