F98

Armature Circuit Open (Early Detection)

Otis · DSD 412 DC Elevator Drive

¿Qué significa F98 ?

This fault indicates that the motor's armature circuit is detected as open when the "Loop Confirm" signal activates, typically during the initial pre-loading sequence. This condition prevents the drive from establishing proper control of the motor and indicates a critical disconnection in the power path.

Causas comunes

  • A physical break or disconnection in the motor armature circuit wiring.
  • The main armature contactor is not closed or has failed to make proper contact.
  • Faulty "Loop Confirm" sensor or feedback circuit providing an incorrect status of the armature circuit.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Power down the drive, then inspect all connections in the motor armature circuit (e.g., motor terminals, contactor terminals) for looseness or damage.

  2. 2

    Measure the resistance across the motor armature terminals to verify winding integrity and continuity.

  3. 3

    Verify the main armature contactor is picking and its main power contacts are closing when commanded.

  4. 4

    Check the wiring and functionality of the "Loop Confirm" feedback signal to ensure it accurately reflects the armature circuit status.