037

Starting Frequency Exceeds Jogging Frequency

Omron · MX2 Inverter

¿Qué significa 037 ?

This warning indicates that the inverter's starting frequency (b082) is set higher than the jogging frequency (A038). This inconsistency can cause an abrupt speed change when transitioning from a jog command or if jogging is initiated at startup, potentially leading to jerky motion or mechanical stress.

Causas comunes

  • b082 (Starting Frequency) was manually configured to a value exceeding A038 (Jogging Frequency).
  • A038 (Jogging Frequency) was inadvertently lowered to a value below the configured b082.
  • An inconsistent parameter setup where the drive attempts to start at a frequency higher than its defined jog speed.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Access parameters b082 (Starting Frequency) and A038 (Jogging Frequency). Compare their values.

  2. 2

    Adjust b082 (Starting Frequency) to be less than or equal to A038 (Jogging Frequency).

  3. 3

    Alternatively, if the application requires b082 to be higher for normal starts, increase A038 (Jogging Frequency) to be equal to or greater than b082.

  4. 4

    Save the parameter changes and power cycle the drive to confirm the settings are active.

  5. 5

    Initiate a jog command and observe the drive's behavior to ensure a smooth transition and correct jog speed.