Traduciendo...
E.OP1 to OP3
Option slot alarm
Mitsubishi Electric · A500 Inverter
¿Qué significa E.OP1 to OP3 ?
This alarm stops the inverter output if a functional alarm occurs in the plug-in option loaded in the corresponding slot (1, 2, or 3). Examples include communication alarms for communication options or contact faults for other types of plug-in options.
Causas comunes
- An alarm detected from a specific option slot (e.g., Option 1, 2, or 3).
- Failure of the hardware in the designated option slot.
- An option card installed in the slot is faulty or incompatible.
- Communication error with the option card in the specified slot.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Confirm the option function settings and operation for the respective option slot.
- 2
Ensure the plug-in option in slot 1, 2, or 3 is connected securely to its connector.
- 3
Check the communication cable associated with the option for wire breakage.
- 4
Verify that the termination resistor for the communication option is fitted properly.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Mitsubishi Electric A500 Inverter