0107
LWD adjustment value out of scale
Kone · V3F25/18 drive
¿Qué significa 0107 ?
The elevator controller prevents the drive, although the V3F25/18 drive itself may allow driving. This indicates an issue with the Load Weighing Device (LWD) mechanical adjustment, parameter settings, or the actual load in the car.
Causas comunes
- LWD mechanical adjustment is incorrect.
- Settings of the load values for LWD are incorrect.
- Incorrect or excessive load in the car.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check the LWD mechanical adjustment.
- 2
Check the settings of the load values for the LWD.
- 3
Check the actual load in the car.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Kone V3F25/18 drive