0101

Drive stop

Kone · V3F25/18 drive

¿Qué significa 0101 ?

Emergency stop or error detected by the V3F25/18 drive diagnostics. This is a general fault indicating that a specific fault code should be present to determine the root cause.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the Kone V3F25/18 drive's display or diagnostic log for any specific fault codes or detailed messages beyond the general 0101.

  2. 2

    Verify the status of all connected emergency stop buttons, safety relays, and safety interlocks in the control circuit, ensuring they are closed and reset.

  3. 3

    Verify the drive's enable and run command signals are present and stable at the control input terminals, using the drive's diagnostic I/O status screen.

  4. 4

    Measure the incoming three-phase supply voltage at the drive's L1, L2, L3 input terminals and compare against the specified nominal voltage.