The IndraDrive MPx02's monitoring system has detected an alarm condition from the optional absolute encoder (e.g., a second motor encoder or an external absolute encoder). This signifies an issue with the absolute position feedback from this auxiliary encoder, which could affect dual-encoder or master-slave configurations, or safety functions.

Causas comunes

  • Loss of absolute position data from the optional encoder (e.g., due to power cycle or battery depletion).
  • Internal fault within the optional absolute encoder itself.
  • Communication error between the drive and the optional absolute encoder.
  • Incorrect optional encoder parameterization in the drive, causing data mismatch or misinterpretation.
  • Damaged encoder battery or supercapacitor (if applicable) for absolute position retention.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the optional absolute encoder's status indicators (LEDs) for any error codes or abnormal behavior as per the encoder manufacturer's manual.

  2. 2

    Verify the communication wiring and protocol settings between the IndraDrive MPx02 and the optional absolute encoder.

  3. 3

    If the optional encoder uses a battery for absolute position retention, check its voltage and replace it if necessary.

  4. 4

    Ensure that the absolute encoder parameters for the optional encoder in the drive are correctly configured for the specific encoder type and application.

  5. 5

    Attempt a re-initialization of the absolute position or a reference run if the absolute position data has been lost, and if the alarm persists, consider replacing the optional absolute encoder.