Position control with encoder 2 not possible
Indramat · IndraDrive MPx02
¿Qué significa E2010 ?
This warning occurs when an attempt is made to switch to encoder 2 for position control, but a second encoder has not been properly defined or configured as the control encoder in the IndraDrive MPx02. This typically happens in operating modes that utilize parameter S-0-0520 (Control word of axis controller) for encoder selection.
Causas comunes
- The second encoder is not physically connected to the drive.
- The second encoder is connected but not correctly configured or enabled as a control encoder in the drive parameters.
- Incorrect selection of encoder 2 in parameter S-0-0520 from the master controller.
- A configuration mismatch between the drive and the application regarding the use of multiple encoders.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify that a second encoder is physically connected to the IndraDrive MPx02 and that all wiring (power, signal) is secure and correct according to the drive's wiring diagram.
- 2
Check the drive's configuration parameters to ensure that encoder 2 is defined and enabled as a control encoder for the relevant operating mode.
- 3
Review the settings for S-0-0520 (Control word of axis controller) to confirm that the attempt to switch to encoder 2 is intended and correctly initiated by the higher-level controller or PLC.
- 4
If the second encoder is present and configured, inspect its functionality and signal quality, ensuring it is providing valid feedback signals.