7950 A800

CC limit switch %.1s+

Heidenhain · NC Control

¿Qué significa 7950 A800 ?

The permissible positive range of traverse for the specified axis was exceeded. This indicates the axis has moved beyond its programmed positive software limit or a physical positive limit switch has been activated.

Causas comunes

  • Permissible positive range of traverse exceeded.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the physical positive limit switch for the affected axis for any damage, obstruction, or incorrect adjustment.

  2. 2

    Verify the setting of parameter MP650 (Positive software limit switch) for the specified axis to ensure it is configured correctly according to the machine's travel limits.

  3. 3

    Inspect the axis position feedback system (encoder) for accuracy and potential errors that could lead to an overshoot.

  4. 4

    Manually jog the axis cautiously in the negative direction to move it off the limit switch, then verify it moves freely without mechanical binding before reaching the positive limit again.