¿Qué significa 2928 E001 ?

The status of NR1 and NR2 inputs is not equal, likely due to incorrect connection of the NR2 input or an internal software error. This indicates a discrepancy in critical safety or feedback signals.

Causas comunes

  • NR2 input incorrectly connected.
  • Internal software error.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the wiring of the NR1 and NR2 inputs for the affected component, ensuring NR2 is connected correctly according to the machine's electrical schematics.

  2. 2

    Inspect the physical connections for looseness, damage, or improper termination at the input terminals.

  3. 3

    Verify the software version of the NC control for any known issues or specific requirements related to NR1/NR2 input handling.

  4. 4

    Perform continuity checks on the NR1/NR2 signal lines and their corresponding safety module or input card to ensure signal integrity.