Motor %.1s: is not turning
Heidenhain · NC Control
¿Qué significa 2209 F2B0 ?
The motor for the displayed axis is not turning when commanded. This indicates a failure in motor activation, power delivery, or mechanical blockage.
Causas comunes
- The motor for the displayed axis is not turning.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify that a valid run command, target position, or speed is being sent to the affected axis by the NC program or manual controls.
- 2
Check the motor power cables for continuity, correct connection to the drive and motor terminals, and absence of damage.
- 3
Inspect the drive for the specified axis for any fault indicators, error messages, or signs of power loss.
- 4
Measure the supply voltage at the drive input and the output voltage/current to the motor when a run command is active to confirm power delivery.
- 5
Check for any mechanical binding or blockage in the axis mechanics that physically prevents the motor from rotating.