DSP error in axis %.2s
Heidenhain · NC Control
¿Qué significa 2187 F010 ?
An error has occurred in the Digital Signal Processor (DSP) within the power stage of the displayed axis. This indicates a critical fault in the axis drive's control electronics.
Causas comunes
- Error in the power stage of the displayed axis.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Power cycle the NC control and the affected axis drive to clear any transient errors and reset the system.
- 2
Inspect the power wiring and feedback connections between the drive, motor, and NC control for the specified axis for any damage, loose terminals, or poor shielding.
- 3
Check for any external mechanical issues, such as binding or collisions, that might have caused an overload condition in the power stage.
- 4
Verify the motor encoder feedback and its cabling, as incorrect or intermittent feedback can lead to power stage instability.
- 5
If the error persists after these checks, consider documenting all relevant machine and program data for review by a service agency.