Traduciendo...
701

Sensor Fault

Fronius · Symo Advanced

¿Qué significa 701 ?

This status code indicates a fault with an external sensor connected to the Fronius Primo GEN24 208-240 inverter, such as a Smart Meter or a temperature sensor. This can be caused by wiring issues, a defective sensor, or incorrect sensor configuration.

Causas comunes

  • Issue with the wiring to the external sensor, such as a loose connection, break, or short circuit.
  • The external sensor itself is defective and providing incorrect or no data.
  • Incorrect configuration settings for the sensor within the inverter's parameters (e.g., sensor type, address).

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the wiring connecting the external sensor to the inverter for continuity, proper termination, and secure connections.

  2. 2

    Verify the sensor configuration settings in the inverter's user interface, ensuring they match the installed sensor type and parameters.

  3. 3

    If possible, test the sensor's functionality independently or temporarily replace it with a known good sensor to isolate the fault.

  4. 4

    De-energize the inverter (switch off AC and DC disconnects), wait for 5 minutes, then re-energize to reset. If the message persists, the sensor may require replacement.

Ver todos los códigos en este manual (41)
Datos técnicos verificados. Última actualización: March 2026