WSD Open
Fronius · Symo Advanced
¿Qué significa 1030 ?
This status indicates that a device connected in the Wired Shutdown (WSD) chain has interrupted the signal line, possibly due to a tripped surge protection device (SPD), the removal of an installed bypass, or a missing trigger device. This condition results in the inverter's operating LED flashing red. It prevents normal operation until the WSD chain integrity is restored.
Causas comunes
- A device in the WSD chain, such as a surge protection device, has interrupted the signal line.
- The bypass installed ex works as standard has been removed from the WSD chain.
- A required trigger device has not been installed in the WSD chain.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
If an SPD surge protection device has tripped, arrange for the inverter to be repaired by an authorized specialist.
- 2
Install the bypass installed ex works as standard or a suitable trigger device into the WSD chain.
- 3
Turn the WSD (wired shutdown) switch to position 1 (WSD primary device) to enable the primary device functionality.