Overcurrent
Fronius · Symo Advanced
¿Qué significa 203 ?
This status code indicates that an overcurrent condition has been detected on the DC input of the Fronius Primo GEN24 208-240 inverter. This typically suggests a short circuit within the solar module strings or other problems with the PV array, or potentially an internal defect in the inverter.
Causas comunes
- A short circuit in one or more solar module strings connected to the inverter.
- Mismatch or other configuration issues within the solar module strings leading to excessive current.
- An internal defect within the inverter's DC input current sensing or protection circuit.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check the solar module strings for correct configuration and functionality, looking for potential short circuits or incorrect wiring.
- 2
Measure the DC input current at the inverter's DC input terminals and compare it against the inverter's maximum input current rating.
- 3
Isolate individual strings to identify the source of the overcurrent.
- 4
De-energize the inverter (switch off AC and DC disconnects), wait for 5 minutes, then re-energize to reset. If the message persists, the inverter may require service.