715

Internal fault (e.g. residual current monitoring unit)

Fronius · Primo GEN24

¿Qué significa 715 ?

The Fronius Primo GEN24 208-240 inverter has detected an internal fault within its residual current monitoring unit (RCMU). This unit is crucial for detecting ground faults and ensuring safety. A fault here means the inverter cannot safely operate and will shut down.

Causas comunes

  • Internal fault (e.g. residual current monitoring unit).

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Perform a full power cycle of the Fronius Primo GEN24 208-240 inverter by opening both the AC circuit breaker and the DC disconnector, waiting, and then reclosing them.

  2. 2

    Ensure there are no actual ground faults in either the AC or DC circuits that might be causing the RCMU to incorrectly trip or fail.

  3. 3

    Check for any moisture ingress or contamination within the inverter that could affect sensitive RCMU components.

  4. 4

    Review the inverter's event log for any preceding fault codes related to insulation faults (e.g., 3xx codes) or grid issues.

  5. 5

    As this is a critical safety component, if the fault persists, contact Fronius service immediately for inspection and potential replacement of the RCMU.

Ver todos los códigos en este manual (60)
Datos técnicos verificados. Última actualización: March 2026