Inverter with battery: no communication

Fronius · Primo GEN24

¿Qué significa 404 ?

The Fronius Primo GEN24 208-240 inverter, configured to operate with a battery, has lost communication with the battery system. This prevents any battery charging or discharging, effectively disabling the energy storage function.

Causas comunes

  • No communication with the battery.
  • Wiring fault (e.g. incorrect or loose cable, crossed data lines).
  • Battery not powered.
  • Incorrect battery address or settings.
  • Battery system internal fault.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check all communication cables (e.g., CAN bus, RS485) between the Fronius Primo GEN24 208-240 inverter and the battery management system (BMS) for proper connection and integrity.

  2. 2

    Confirm that the battery system is powered on, not in sleep mode, and its status indicators (LEDs) are normal.

  3. 3

    Verify the communication protocol settings (e.g., CAN ID, Modbus address) within the inverter's interface align with the battery manufacturer's specifications.

  4. 4

    Inspect the communication cable for any physical damage, breaks, or incorrect pinouts.

  5. 5

    Perform a controlled shutdown and restart of both the inverter and the battery system as per their respective manuals to reset communication.

Ver todos los códigos en este manual (60)
Datos técnicos verificados. Última actualización: March 2026